Gecko Spa Hot Tub S-Class Heater 5.5kw Soldered Tab Style with Gasket SSPA How To Video

(No reviews yet) Write a Review
SKU:
ASPC255E-08E0ET-G
Shipping:
Calculated at Checkout
  • Gecko Spa Hot Tub S-Class Heater 5.5kw Soldered Tab Style with Gasket SSPA How To Video
  • If your S-Class Board has this type of connection where the terminal tabs are soldered to the board this board will work. If you have the newer style where the tabs have a wire in between that is Screwed to the board this heater will work but you would have to reuse the wires. We do offer a newer version in our store with thee wires already on it and with a pressure switch but this heater will not order with the old style tabs.. So make sure you order the correct heater.
  • This heater fits a plastic pack that looks similar to this..
  • Gecko Spa Hot Tub S-Class Heater 5.5kw Soldered Tab Style with Gasket SSPA How To Video
  • Gecko Spa Hot Tub S-Class Heater 5.5kw Soldered Tab Style with Gasket SSPA How To Video
  • Gecko Spa Hot Tub S-Class Heater 5.5kw Soldered Tab Style with Gasket SSPA How To Video
  • Gecko Spa Hot Tub S-Class Heater 5.5kw Soldered Tab Style with Gasket SSPA How To Video
  • Gecko Spa Hot Tub S-Class Heater 5.5kw Soldered Tab Style with Gasket SSPA How To Video
MSRP: $259.99
$205.99
— You save $54.00

Description

You are buying a Complete Replacement 5.5KW Heater Assembly that fits a Gecko SSPA or Spa Builders Pack. This Heater Assembly includes the Tube, Element, Split nuts and Gaskets. It has a 15" length and 2" union that measure 3" inside. There are two variations of this heater and this model is for systems that have the original heater design with removable wires or soldered tabs like pictured.

The pressure switch is not included with this heater. You can either reuse yours or see below for the two most common switches used by Gecko on the S-Class pack

Pressure Switch, Choice # 1: Universal Tecmark Low Voltage Pressure Switch, 1/8" Mpt, 1 Amp
Pressure Switch, Choice # 2: Pressure Switch 1/8" mpt 1 Amp Hot Tub Spa Part Universal How To Video

If you have the newer style heater that has wires or pigtails soldered to the heater terminals with copper ends then this heater is not correct. We do carry that version heater here: Gecko Spa Hot Tub S-Class Heater 5.5kw w/ Pigtails and Gasket, SSPA How To Video

 

Housing Configuration Straight
Heater Length 15"
Lead End Terminal Location 5-3/4"
Threaded Tap Orientation 12 O`Clock
Threaded Tap Location 9-7/8" From Leading End
Kilowatts 1.5kW, 5.5kW
Voltage 115v, 230v
Sensor Stud Orientation None
Mounting Stud Type Fixed
Heater Size 2"
Heater Application Caldera, Gecko, Nordic, Dynasty, Gulf Coast Spas, Hydro Spas and others

 

Watch the video for tips on how to diagnose this part. Normally on this system you will have 3 dots flashing on the topside showing a Flow Code but three dots can also mean a hi limit code if there is a tiny red light lite on the lower right of the board. If it is a hi limit code that means the heater overheated at some point and you cannot clear the three dots with the red light unless you power down and back up. Some of the causes of a hi limit code can be a stuck closed heater relay, a combination of no GFCI Breaker and a hole in the heater element shorting the element to ground and keeping it on, bad board or hi limit sensor.. The causes of 3 dots and no red light which is a Flow Code could be a stopped up filter, pump #1 not operating sometimes or at all, a faulty pressure switch not closing when it has water movement...If all systems are working with no 3 dots code but no heat you would verify incoming voltage, proper voltage to the heater and then test the heater to see if it is open... Thanks, Spa Guy 
 
sspa,s-spa,gecko,s-class,scales,s class,heater, element, pressure switch,3 dots, flow code, flo code,9920-100338,9920-100339,spa builders, dynasty, nordic,pack,control,plastic, 