Circuit Board, Sundance / Jacuzzi, 880/J-400 LCD, 2 Pump, "Perma Clear",**Pump 1=1Spd, Pump 2 =1Spd, w/Circ Pump
- SKU:
- HTP6600-OLR
- Shipping:
- Calculated at Checkout
-
Circuit Board, Sundance / Jacuzzi, 880/J-400 LCD, 2 Pump, "Perma Clear",**Pump 1=1Spd, Pump 2 =1Spd, w/Circ Pump
-
Circuit Board, Sundance / Jacuzzi, 880/J-400 LCD, 2 Pump, "Perma Clear",**Pump 1=1Spd, Pump 2 =1Spd, w/Circ Pump
-
Circuit Board, Sundance / Jacuzzi, 880/J-400 LCD, 2 Pump, "Perma Clear",**Pump 1=1Spd, Pump 2 =1Spd, w/Circ Pump
-
Circuit Board, Sundance / Jacuzzi, 880/J-400 LCD, 2 Pump, "Perma Clear",**Pump 1=1Spd, Pump 2 =1Spd, w/Circ Pump
Description
This part is a Circuit Board, Sundance / Jacuzzi, 880/J-400 LCD, 2 Pump, "Perma Clear",**Pump 1=1Spd, Pump 2 =1Spd, w/Circ Pump.
This Sundance/Jacuzzi 880 circuit board is for (2) single speed pump systems. This PCB was formerly 6600-180 or 6600-098. Used in 2005-4/2009 Altamar, Cameo, Capri, Marin, Optima, Majesta with Two 1-Speed Jet Pumps.
Circuit Board Application | Sundance |
Circuit Board Model | 880 |
Circuit Board Type | New |
Manufacturers Part Number | 6600-OLR |
System | Year | Details/Models |
J-400 LCD | 2006 Mid 12/2009 | J-480, J-470, J-465, J-460 |
Jumper settings are as follows:
JP19 Jumper Bank
JP19-1 - On - Celcius, Off - Fahrenheit
JP19-3 - On - 50Hz, Off - 60Hz
JP19-5 - On - LED Lights, Off - Incandescent Lights
JP19-7, 9, and 11 are not used
JP9 Jumper Bank
JP9-1 - On - Enables Trouble Log, Off - Disables Trouble Log
JP9-3 - On - Enables ILOC, Off - Disables ILOC
JP9-5 - NOT USED
JP9-7 - On - 60A Logic Allows 2 Pumps on w/Heater, Off - 50A Logic Forces Heater Off When More Than 1 Pump is ON
JP9-9 - On - Enables Pump 2 on -728/-730 pcb's and Pump 3 on -392 pcb, Off - Disables
JP9-11 - On - 40A Logic Forces Heater off w/ Any Pump in Hi, Off - Disables
JP9-13 - On - Allows Only 1 Pump w/Blower to Operate at a Time, Off - Blower, Pump 1, Pump 2 Can Operate at the Same Time
JP9-15 - On - Recall All Factory Settings, Off - The Jumper Must Remain Off During Normal Operation
JP19 Jumper Bank
JP19-1 - On - Celcius, Off - Fahrenheit
JP19-3 - On - 50Hz, Off - 60Hz
JP19-5 - On - LED Lights, Off - Incandescent Lights
JP19-7, 9, and 11 are not used
JP9 Jumper Bank
JP9-1 - On - Enables Trouble Log, Off - Disables Trouble Log
JP9-3 - On - Enables ILOC, Off - Disables ILOC
JP9-5 - NOT USED
JP9-7 - On - 60A Logic Allows 2 Pumps on w/Heater, Off - 50A Logic Forces Heater Off When More Than 1 Pump is ON
JP9-9 - On - Enables Pump 2 on -728/-730 pcb's and Pump 3 on -392 pcb, Off - Disables
JP9-11 - On - 40A Logic Forces Heater off w/ Any Pump in Hi, Off - Disables
JP9-13 - On - Allows Only 1 Pump w/Blower to Operate at a Time, Off - Blower, Pump 1, Pump 2 Can Operate at the Same Time
JP9-15 - On - Recall All Factory Settings, Off - The Jumper Must Remain Off During Normal Operation