XP2 2.0 HP Impeller Aqua-Flo 2 1/8" Eye with 1/4" Vane Width 4 3/8" OD 230/10A or 115/16A

(2 reviews) Write a Review
SKU:
HTP35-402-1412
Shipping:
Calculated at Checkout
  • Impeller Aqua-Flo XP2 2.0 HP 2 1/8" Eye with 1/4" Vane Width 4 3/8" OD 230/10A or 115/16A
  • Impeller Aqua-Flo XP2 2.0 HP 2 1/8" Eye with 1/4" Vane Width 4 3/8" OD 230/10A or 115/16A
  • Impeller Aqua-Flo XP2 2.0 HP 2 1/8" Eye with 1/4" Vane Width 4 3/8" OD 230/10A or 115/16A
  • Impeller Aqua-Flo XP2 2.0 HP 2 1/8" Eye with 1/4" Vane Width 4 3/8" OD 230/10A or 115/16A
  • Impeller Aqua-Flo XP2 2.0 HP 2 1/8" Eye with 1/4" Vane Width 4 3/8" OD 230/10A or 115/16A
  • Impeller Aqua-Flo XP2 2.0 HP 2 1/8" Eye with 1/4" Vane Width 4 3/8" OD 230/10A or 115/16A
  • Impeller Aqua-Flo XP2 2.0 HP 2 1/8" Eye with 1/4" Vane Width 4 3/8" OD 230/10A or 115/16A
  • Impeller Aqua-Flo XP2 2.0 HP 2 1/8" Eye with 1/4" Vane Width 4 3/8" OD 230/10A or 115/16A
  • Impeller Aqua-Flo XP2 2.0 HP 2 1/8" Eye with 1/4" Vane Width 4 3/8" OD 230/10A or 115/16A
MSRP: $44.99
$38.99
— You save $6.00

Description

This is a 2HP Impeller with a 2 1/8" Eye width and 1/4" Vane width and 4 3/8" OD for an Aqua-Flo 48 or 56 Frame Wet End 2.0HP Motor would be about 10.0 Amps on high speed at 230V or 16.0 Amps High Speed at 115V. This Impeller fits between the Face and the Volute of an Aqua-Flo XP2 or FMXP2 Wet End. I would advise replacing the Seal when you replace the Impeller. Choose with care, I Do Not accept returns so be sure these are correct before ordering! Visit our Store as we also offer these and other associated products and accessories for your Spa. Note: A 115v motor that uses a 1 HP Impeller would show about 11-12.0 Amps on high speed a 230V motor would show about 8.0 Amps on High. See chart below for other Horsepowers. Do Not choose a Larger Impeller thinking that it will make your Hot Tub Stronger it will only damage the Motor and make it run hot on high speed. To determine the HP refer to the chart below.. The difference between a 48 or 56 Frame wet end is the spacing of the Motor Thru bolts. The 48 Frame will be 3 5/8" between or 5 3/16" in a X Pattern and have a 1/4" Bolt Head and the 56 Frame will be 4 1/8" Between or 5 3/4" in a X Pattern and have a 5/16" Bolt Head. 91694200

This Impeller uses PS-200 Seal kits that can be found Click Here.


Note: A 115v motor that uses a 2 HP Impeller would show about 15-16.0 Amps on high speed a 230V motor would show about 10.0 Amps on High. See chart below for other Horsepowers. 
Do Not choose a Larger Impeller thinking that it will make your Hot Tub Stronger it will only damage the Motor and make it run hot on high speed as well as there are (3) different size wear rings on the impellers so if you choose a different size impeller your wear ring may not work. Measure your wear ring to determine which impeller section you should be in.. 2 1/8", 2 3/8" or 2 5/8" look for the eye sizes in the impeller description area...
 
To determine the HP refer to the chart below.. 
The difference between a 48 or 56 Frame wet end is the spacing of the Motor Thru bolts. 
The 48 Frame will be 3 5/8" between or 5 3/16" in a X Pattern and the 56 Frame will be 4 1/8" Between or 5 3/4" in a X Pattern. 
You must go by the Amperage Sticker on the motor not stickers on the Wet End or Motor especially the BHP Stickers. 
Look on the label of the motor for the two amperages if you have a 2 speed pump or if its a single speed look for a single amperage. An example will look something like this: 10.0/3.5  The 10.0 is the high amperage in this example. 
 
115V Chart Below
3/4HP 8-9 Amps
1HP 11-12 Amps 
1.5HP 16-17 Amps 
2HP 19-20 Amps. 2HP would be very rare
 
230V Chart Below
8.0 = 1 HP
10.0 = 2 HP
12.0 = 3 HP
14.0 = 4 HP
16.0 = 5 HP
 
NOTE: Your pump or motor may say a different Horse Power than what you see here, DO NOT go by what is listed on the motor, go by the amperage on the label. 
NOTE for the NOTE: TRUST ME ON THIS, everybody lies about their Horse Power. But the amperage does not lie. Most people are told incorrectly that they have 5 HP pumps.
If you do the math two 230V 5 HP pumps at 16 amps is: 32 amps. Plus a 5.5 KW heater is: + 21 amps.  
That means with both pumps running and the heater on it will draw  = 53 AMPS
I bet your HOT TUB is on a 50 AMP breaker…... Therefore contrary to what you have been told you DO NOT have a 5 or 6 or 7 Hp pump.
 
Impeller Type
  Closed Face
Impeller Diameter OD 4-3/8"
Vane Width ID 1/4"
Eye Diameter OD 2-1/8"
Eye Length 11/16"
Impeller Width OD 1/2"
Seal Seat Depth 1/8"
Shaft Length 1-1/2"
Shaft Diameter OD 5/8"
Seal Seat Diameter OD 1-1/4"
Manufacturer AquaFlo/Gecko
Pump Application XP2
View AllClose

2 Reviews

  • 5
    perfect

    Posted by Kelly Carpenter on Jun 28th 2017

    This impeller fit perfect on my Aquq Flo xp2 10.7 amp pump. First, since the original impeller had no markings, I had no ideal what to replace it with. The spa guys YouTube videos were incredibly helpful. So thank you for that. Secondly, price and shipping were great. I always appreciate being able to track the package once it ships. Excellent overall buying experience!

  • 5
    perfect fit

    Posted by Unknown on Sep 15th 2016

    Was able to rebuild 2 hot tub pumps saved me hundreds Thanks to the detailed videos and customer service

View AllClose